Numerical model for magnetic fluid hyperthermia in a realistic breast phantom: calorimetric calibration and treatment planning

Abstrakt

This paper aims to apply a proposed, based on calorimetric measurements, a reliable numerical model for magnetic fluid hyperthermia (MFH) treatment planning of breast cancer. Furthermore, we perform a comparative analysis of magnetic nanoparticles (MNPs) and tumour tissue interactions by means of the magnetic-field-dependent Néel and Brownian relaxation times. The analysis was based on an anatomically correct breast model (developed in-house) and a modified linear response theory, which was applied to investigate the heat dissipation from the magnetic nanoparticles dispersed in the breast tumour. The calculations of the single-domain magnetic power losses were conducted for a case where the magnetic field value and the applied frequency were known, but also for the different concentrations of the MNPs in the tumour. Two scenarios were considered: The MNPs mobilised and immobilised in the tumour. In parallel, the eddy currents effect, together with the related temperature distributions, were considered in order to analyse safety issues. By changing the MNP concentration in the tumour, the corresponding temperature distributions were calculated. The eddy current effect, together with the related temperature distribution, were considered in order to analyse safety issues. Varying the MNP concentration in the tumour, the corresponding temperature distribution was calculated. Moreover, the cumulative equivalent minutes at 43 ℃ were analysed. In the anatomically correct breast phantoms, the tissue location can lead to “hot spots” due to the eddy current effect and subsequently to the high gradients of the temperature. That is why the analysis of safety issues related to the overheating side effect should be taken into consideration during the treatment planning of magnetic fluid hyperthermia. The phenomenon of heat dissipation from MNPs is very sophisticated and depends on their concentration, the distribution and the relaxation mechanism in the tumour, together with magnetic field strength and frequency. Furthermore, we inferred that the phenomenon of heat dissipation from MNPs equally depends on MNP-tissue interactions, and it can lead to 30% differences in the power assessment. Nevertheless, the aforementioned factors should be considered in parallel using anatomical, volume-dependent models to enhance the efficiency of in vivo treatment.

Autorzy

Mahendran Subramanian
Mahendran Subramanian
artykuł
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES
Angielski
2019
20
18
s. 1-12
otwarte czasopismo
CC BY 4.0 Uznanie autorstwa 4.0
ostateczna wersja opublikowana
w momencie opublikowania
2019-09-19
140
4,556
10
16